EzCad2UNI User’s Manual
direction for Figure 10-20 and lower the coefficient on the X axis direction for Figure 10-21.
Figure 10-19 Your Design
Figure 10-20 Marked Work
Figure 10-21 Marked Work
This item indicates the parallelogram correction coefficient, and the default is 1.0 (range
from 0.875 – 1.125). If your design is as Figure 10-19 shows but the marked work is Figure 10-22,
you will have to adjust this parameter to correct it.
Figure 10-22 Marked Work
Scale: It refers to the flex percentage, and the default is 100%. This parameter will be
adjusted when the trim size marked is different from the setting size. If the trim size is smaller
62
All rights reserved